Communicating with an OBC

There are currently three primary methods for users to communicate directly with their OBCs:

  • Via a debug UART port
  • Via SLIP using a UART port
  • Via an ethernet port (not supported by all boards)

Debug Console

Each board will have some debug port available, which will then be connected to your computer via USB. See the appropriate KubOS for the {OBC} > Working with the {OBC} document for more information.

Running Locally

If you are not using the Kubos SDK image and are instead running everything locally, you will need to manually set up a serial connection.

Connect your OBC to your host computer and then determine the device name which it was assigned. It will likely be a /dev/ttyUSB* device for Linux users, a dev/tty.usb* device for OSX users, and a COM* device for Windows users.

Open your terminal application of choice (PuTTY, minicom, etc) and set up a connection with the following configuration values:

Setting Value
Baudrate 115200
Bits 8
Parity N
Stop Bits 1

Minicom

In case you have not ever set up a serial connection to a device before, here are the instructions to set up a connection using minicom:

  • Execute this command: minicom -s
  • The “configuration” menu will be displayed. Use the arrow keys to navigate to “Serial port setup” and press Enter
  • Press ‘A’ to navigate to the “Serial Device” field. Update the field with the serial debug device name. Press Enter to apply the change
  • Press ‘F’ to toggle “Hardware Flow Control” to “No”
  • Press Enter to exit this submenu
  • Navigate down to “Exit” (not “Exit from Minicom”!) and press Enter to exit the configuration menu and start the serial connection

Using the SDK

If the target board is correctly connected to your host computer, you should see a /dev/ttyUSB* device in your SDK instance. The VM is set up to automatically forward any FTDI cables that connect to a /dev/FTDI device for ease-of-use.

The Vagrant image comes pre-packaged with a minicom serial connection configuration file. You can connect with this configuration file using this command:

$ minicom kubos

Logging In

Once connected, you can log in using either a user that you’ve created, the default kubos user, or root. The kubos and root users both have a default password of ‘Kubos123’.

Fully logged in, the console should look like this:

Welcome to Kubos Linux

Kubos login: kubos
Password:
/home/kubos #

Ethernet

Some OBCs support communication via an ethernet port. Once configured, this port can be used as an alternate method to access the board’s shell interface and to transfer files.

Determining a Suitable IP Address

KubOS does not use DHCP, so all IP addresses are statically defined.

Warning

All OBCs which support ethernet connections come with a predefined IP address. It is very likely that this default address will be incompatible with whatever network the OBC is connected to. As a result, you will need to do some research in order to determine a suitable IP address for your OBC.

If you are connecting your OBC to a network switch (which gives it the ability to access the internet and potentially be accessed remotely), find the IP address your host machine is using for the same network, and then pick a different host number (the last number in the IP address).

Note

If you are connecting your OBC to a large corporate network, you might need to contact your IT department in order to be assigned an IP address.

If you are connecting your OBC directly to your host computer’s ethernet port, you’ll need to first determine and/or set the IP address of the host computer for that connection.

Commands like ifconfig (or ipconfig for Windows users) should display the current address of the ethernet connection. Worth noting, it may be necessary to first connect the OBC to the host computer in order for the connection to appear in the command output.

Please consult your relevant OS’ documentation for instructions on setting a static IP address.

Configuring the OBC

Connect an ethernet cable from the OBC to either your computer or an open network port.

Log into the OBC using the debug console and then edit /etc/network/interfaces. Update the IP address field to be an address of your choosing.

Once updated, run the following commands in order to make the OBC use the new address:

$ ifdown eth0; ifup eth0

The address can be verified by running the ipaddr command

SLIP

Using SLIP over a UART port allows users to communicate with a target OBC as though it has a normal network connection set up. This is most useful for communicating with OBCs which do not provide an ethernet port.

All supported boards include a SLIP configuration in their /etc/network/interfaces file.

In order to communicate with an OBC from the Kubos SDK, or from a host machine running Linux, users will need to do the following:

  • Connect an FTDI cable to the pins of the UART port (please refer to the UART section of the appropriate KubOS for the {OBC} > Working with the {OBC} document for details about the default SLIP UART port for the board)

    • Ground -> Ground
    • TX -> RX
    • RX -> TX
    • RTS -> CTS (Might not be available on all boards/UART ports)
    • CTS -> RTS (Might not be available on all boards/UART ports)
    • Vcc -> ignore

    FTDI cables typically have the following pinout:

    Pin Color Function
    1 Black Ground
    2 Brown CTS
    3 Red Vcc
    4 Orange TX
    5 Yellow RX
    6 Green RTS
  • Connect the USB portion of the FTDI cable to the host machine

  • Issue ls /dev and identify the /dev/ttyUSB* device associated with the FTDI cable

  • Set up the SLIP device

    • If the UART port has RTS/CTS available, issue the following:

      $ sudo slattach -s 115200 -p cslip {USB-device} &
      
    • Otherwise, issue this command instead:

      $ sudo slattach -FL -s 115200 -p cslip {USB-device} &
      
  • Define a new network interface for the device:

    $ sudo ifconfig sl0 192.168.0.1 pointopoint 192.168.0.2 up
    
  • Finally, ensure that the SLIP traffic will be routed to the SDK’s host IP:

    $ sudo route add 192.168.0.1 dev lo
    

Worth noting, the baud rate, protocol, and IP addresses may all be changed. In this case, the corresponding values in the OBC’s /etc/network/interfaces file should also be changed to match.

Communicating via SSH

Once a board has been given a valid IP address (via ethernet or SLIP), you can create an SSH connection to it.

This can be done from either the SDK or your host machine.

To connect from the command line, run ssh kubos@{ip-address}. You will be prompted for the kubos account password.

You can also use a tool, like PuTTY, to create an SSH connection.

File Transfer

Once your board is connected and running you can begin transferring files to it. There are two supported methods of file transfer: scp and ZMODEM over minicom.

SCP

Transferring files using scp requires the board to have an IP connection using either ethernet or SLIP.

Once the IP address has been set, you can transfer files to and from the stack using the scp command. This command can be run from either the SDK or your host machine.

For example, if I wanted to send a file on my host machine, test.txt, to reside in the kubos account’s home directory, given a stack IP of 10.50.1.10, I would enter:

$ scp test.txt [email protected]:/home/kubos

Note

While file transfer can be done over a SLIP connection, it is significantly faster and more reliable when done over an ethernet connection instead (for boards which have an ethernet port available)

Minicom

If your board only has serial connections and there is no spare UART for SLIP, you can still transfer files over the debug serial console using minicom.

Connect to the board through minicom (the file transfer protocol is not guaranteed to work with any other terminal program)

$ minicom kubos

Login to the board

Welcome to minicom 2.7

OPTIONS: I18n
Compiled on Feb  7 2016, 13:37:27.
Port /dev/FTDI, 21:26:43

Press CTRL-A Z for help on special keys


Welcome to Kubos Linux
(none) login: root
Password:
Jan  1 00:00:11 login[210]: root login on 'ttyS0'
~ #

Navigate to the location you’d like the received file to go.

~ # mkdir righthere
~ # cd righthere
~/righthere #

Issue the zModem command to prep the board to receive a file

$ rz -bZ

Press Ctrl+a, then press s to open the minicom file transfer dialog.

+-[Upload]--+
| zmodem    |
| ymodem    |
| xmodem    |
| kermit    |
| ascii     |
+-----------+

Select zmodem

+-------------------[Select one or more files for upload]-------------------+
|Directory: /home/vagrant                                                   |
| [..]                                                                      |
| [linux]                                                                   |
| [newprj]                                                                  |
| minicom.log                                                               |
|                                                                           |
|              ( Escape to exit, Space to tag )                             |
+---------------------------------------------------------------------------+

               [Goto]  [Prev]  [Show]   [Tag]  [Untag] [Okay]

Select the file to send:

Press g to open the Goto dialog and navigate to the desired folder (full pathname required).

Press enter to open the file selector dialog and specify the file you want within the current folder.

+-------------------[Select one or more files for upload]-------------------+
|Directory: /home/vagrant/linux/build/kubos-linux-isis-gcc/source           |
| [..]                                                                      |
| [CMakeFiles]                                                              |
| CMakeLists.txt                                                            |
| CTestTestfile.cmake                                                       |
| cmake_install.cmake                                                       |
| linux                                                                     |
| linux.map                                                                 |
|                +-----------------------------------------+                |
|                |No file selected - enter filename:       |                |
|                |> linux                                  |                |
|                +-----------------------------------------+                |
|                                                                           |
|              ( Escape to exit, Space to tag )                             |
+---------------------------------------------------------------------------+

               [Goto]  [Prev]  [Show]   [Tag]  [Untag] [Okay]

You should see a progress dialog as your file is transferred to the board.

+-----------[zmodem upload - Press CTRL-C to quit]------------+
|^XB00000000000000rz waiting to receive.Sending: linux        |
|Bytes Sent:  41984/  99084   BPS:8905     ETA 00:06          |
|                                                             |
|                                                             |
|                                                             |
|                                                             |
|                                                             |
+-------------------------------------------------------------+

Once file transfer is complete, you should be able to press enter and use your new file

+-----------[zmodem upload - Press CTRL-C to quit]------------+
|^XB00000000000000rz waiting to receive.Sending: linux        |
|Bytes Sent:  99084   BPS:7982                                |
|                                                             |
|Transfer complete                                            |
|                                                             |
| READY: press any key to continue...                         |
|                                                             |
+-------------------------------------------------------------+

Press Ctrl+a, then q to bring up the dialog to exit minicom. Hit enter to quit without reset.